polarik-azul

THE CEILING-MOUNTED MONOBLOCK UNIT

IDEAL FOR REDUCED SPACES.

bulb

OPTIMISED FOR EACH IMPLEMENTATION

UNIQUE AND SMART

CEILING MOUNTING

Ceiling mounting is the ideal installation solution
whenever space is limited.

Additionally the monoblock unit is operated
by a remote control panel.

 

Polarik-DECKENMONTAGE
Plug & Play
Quick and easy change of user profiles.
Optional remote monitoring via ModBus interface.
Defrosts can be set up to 6 times per day during opening hours and 6 times.
Specific temperature and timeout parameters for each scheduled defrost (e.g. complete defrost during downtime).
Alternatively “smart defrosting” automatically defrosts the heat exchanger after a constant check of the values between the defrosting sensor and the sensor detecting the temperature.
soffitto-ghost@2x

Forward-thinking:

our monoblock unit is designed for the future.

Conditions for volume calculation

Medium Temperature

Cold room insulation: 100 mm
Charge density: 250 kg/m³
Specific heat of the product: 3,22kJ/kg*K
Product inlet temperature: +15 °C
Compressor running time: 18 h
Goods transshipment: 7%

Low Temperature

Cold room insulation: 100 mm
Charge density: 250 kg/m³
Specific heat of the product: 1,84 kJ/kg*K
Product inlet temperature: -10 °C
Compressor running time: 18 h
Goods transshipment: 7%

Cold room volume and cooling capacity

Ambient temperature [°C]Cold room temperature [°C]Polarik
7TN1
Polarik
15TN2
Polarik
20TN2
Polarik
40TN3
+25-5m36,813,816,442,0
w1420175022603880
0m37,415,821,445,7
w1840226030204750
+5m38,218,724,849,2
w2200268039005800
+35-5m35,812,515,733,9
w1220152018803250
0m36,814,118,437,1
w1450196025204140
+5m37,515,220,640,1
w1880245033805180
+43-5m35,18,113,827,8
w940125016802960
0m35,910,814,931,7
w1220168022303650
+5m37,112,116,334,9
w1530208031204620

Ambient temperature [°C]Cold room temperature [°C]Polarik
5TL1
Polarik
10TL2
Polarik
15TL3
+25-25m36,211,720,7
w62019202400
-20m37,913,624,1
w86025403280
-15m38,215,428,9
w114031404520
+35-25m33,87,314,2
w52014501840
-20m34,59,518,2
w71020802620
-15m35,311,824,3
w92026003510

TABLE FEATURES

Medium Temperature

DescriptionUnitPolarik
7TN1
Polarik
15TN2
Polarik
20TN2
Polarik
40TN3
Temperature range of
the cold room
º CMT + 10 º C / - 5 º C
Max. volume of the
cold room
10152040
VoltageV1 ˜ 2301 ˜ 2303 ˜ 4003 ˜ 400
FrequencyHz50505050
Cooling capacityW1590207925604370
Heat output to the
environment
W2291290436906120
Compressor energy
consumption
W70182511301750
EER12,272,522,272,5
Current consumption
LRA
A28302338
Current consumption
FLA
A5,75,17,510
Type of defrostingHGHGHGHG
Evaporator air flowm³ / h750110011002 x 1100
Condenser air flowm³ / h750110011002400
Degree of protectionIP34
Max. external
temperature
º C43
RefrigerantTypeR-513A
GWP2631,4
CO2 equivalentt CO20,2530,3790,410 0,884
Amount of refrigerantg400600 6501400
Power supply cable
length
m2222
Evaporator air throwm2,5445
Dimensions
drawings No.
1223
Weight kg86112114122
ColourRAL9010 / 7024

Low Temperature

DescriptionUnitPolarik
5TL1
Polarik
10TL2
Polarik
15TL3
Temperature range of
the cold room
º CLT -15 º C / - 25 º C
Max. volume of the
cold room
51015
VoltageV1 ˜ 2303 ˜ 4003 ˜ 400
FrequencyHz505050
Cooling capacityW73816221968
Heat output to the
environment
W129832054018
Compressor energy
consumption
W56015832050
EER11,321,210,96
Current consumption
LRA
A212330
Current consumption
FLA
A2,42,84
Type of defrostingHGHGHG
Evaporator air flowm³ / h75011002 x 1100
Condenser air flowm³ / h75011002400
Degree of protectionIP34
Max. external
temperature
º C35
RefrigerantTypeR-452A
GWP22140
CO2 equivalentt CO2 0,6421,498 2,568
Amount of refrigerantg300 7001200
Power supply cable
length
m222
Evaporator air throwm2,545
Dimensions
drawings No.
123
Weight kg86124 124
ColourRAL9010 / 7024

Cooling capacity at an ambient temperature of +32 °C and at an internal temperature of the cold room of +2 °C (cold room with 100-mm insulation + insulated floor)

1 - EER - Efficiency value obtained from the ratio between energy consumption and cooling capacity      2 - GWP - Global warming potential

Cooling capacity at an ambient temperature of +32 °C and at an internal temperature of the cold room of -18 °C (cold room with 100-mm insulation + insulated floor)

1 - EER - Efficiency value obtained from the ratio between energy consumption and cooling capacity      2 - GWP - Global warming potential

  • This field is for validation purposes and should be left unchanged.

Get in touch with us for more information
or to request a quote.